USER
MANUAL
Copyright ©2024 - All Rights Reserved
Love Your Lights and Wall Panel Pro are Registered
Trademarks of Pro Church Lights
PowerCon is a registered trademark of Neutrik
prochurchlights.com
WALL
PANEL
PRO
™
THANK YOU
for purchasing the WALL PANEL PRO™ by Pro Church Lights
VIEW THE SETUP VIDEOS
or visit https://support.prochurchlights.com/setup-guides
Scan QR code using mobile device
prochurchlights.com
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received. including interference that may cause
undesired operation.
Manufactured for Pro Church Lights
Distributed by Pro Church Lights USA LLC
Manufactured in China - Serviced in USA
©2024 All Rights Reserved
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
SPECIFICATIONS
DMX Control 512ch and 1024ch Models
Input Current AC100-240v, 50/60hz
Amp Draw 0.50 amps
Wall Panel Material Tempered Glass
Rack Unit Material Metal
IP Rating IP20 / Indoor Use Only
CONTENTS
prochurchlights.com
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
What's In The Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Getting to Know Your Pro Church Lights Device . . . . . . . . . . . . 5
Menu Functions Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Setting Up Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing Wall Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Set Up Settings and Presets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USING YOUR WALL PANEL PRO™
WARNING - Cancer and Reproductive Harm
For more information visit:
www.P65Warnings.ca.gov
SAVE THESE INSTRUCTIONS
prochurchlights.com
WARNING - Risk of electrical
shock and fire hazard. Use
precaution and awareness when
using this electrical device.
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
WARNING
ALWAYS properly ground to
maintain Class 1 Protection.
DO NOT power the unit if the
cord is frayed or damaged.
DO NOT plug this unit into a
dimmer switch or dimmer pack.
DO NOT expose to liquids, rain or
moisture.
ALWAYS disconnect from power
before making any type of
connection.
This device is for indoor use only.
Using this device in any other
way will void its warranty and
cause unsafe operation.
Regularly inspect the device and
power cord. DO NOT use the
device if there is damage to the
power cord or plug. If the
appliance malfunctions or
has been damaged in any way,
immediately stop use and call
Customer Service. Return the
device to Pro Church Lights for
examination, repair, or
adjustment.
DO NOT remove the cover or service
inside the unit.
ALWAYS use AC power that
complies with local building and
electrical codes and has both
overload and ground fault
protection.
ALWAYS check that your voltage
is compatible with this device
before plugging in the device.
10
WHAT'S IN THE MAIN UNIT BOX
WALL PANEL PRO™ Main Unit
prochurchlights.com
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
3’ 3-Pin DMX Cable
Cat5 Cable
Power Cable
WHAT'S IN THE WALL PANEL BOX
WALL PANEL PRO™ Wall Panel
4 Phillips Head Screw
4 Wall Anchors
GETTING TO KNOW YOUR DEVICE
prochurchlights.com
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
WALL
PANEL
PRO
™
USB
DISPLAY
MENU
UP
ENTER
DOWN
PRESET
SPEED
WALL
CONSOLE
STOP
RECORD
BLACK
OUT
OFF
ON
Diagram showing front of 512 & 1024 models
10
11
12
13
Number
Description
Function
USB Port
USB for backing up presents and settings
DISPLAY
Displays set up functions
MENU
Used to access the different menu items
UP
Used to adjust settings
DOWN
Used to adjust settings
ENTER
Confirms settings
PRESET 1-8
Buttons for saved presets
+SPEED-
Used if utilizing chase mode
WALL
Activates wall panel mode.
Flashing indicates "active". Static indicates "locked".
10
CONSOLE/STOP
Activates console mode.
When saving presets, this is used as the “stop” button.
11
RECORD
Activates recording of presets.
12
BLACKOUT
Stops DMX output
13
Power switch
Turns unit on and off
GETTING TO KNOW YOUR DEVICE CONT’D
prochurchlights.com
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
POWER IN
DMX OUT
RS485
RS232
PANEL
AUDIO
AUDIO
MIC
MIC
IN RECORD
70SO23060008062
AUDIO
MIC
70SO23060008062
Diagram Showing Rear of 512 Channel Version:
Diagram Showing Rear of 1024 Channel Version: (The 1024 version has a 2nd DMX IN/OUT port)
DMX OUT A
RS485
RS232
PANEL
AUDIO
MIC
IN RECORD A
DMX OUT B
IN RECORD B
Number
Description
Function
POWER INPUT
AC 88 - 256V 50/60Hz
DMX OUT
DMX output to fixtures or distributor
RS232
RS232 control port
PANEL/CENTRAL
Main wall panel connection port
AUDIO
Allows for audio triggers
AUDIO & MIC
Switch between audio port or mic for triggers
MIC
Mic for sound triggers
IN RECORD
DMX input from console
RS485
Allows for additional rack units to be connected
10
DMX OUT B
2nd Universe DMX output
11
IN RECORD B
2nd Universe DMX input
10
11
prochurchlights.com
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
MENU FUNCTIONS REFERENCE
MENU ITEMS AND FUNCTIONS
Map Menu
Function
1. UNIT ID
Set Device ID (used if multiple main units are being used)
2.PLAY MODE
Single (recommended mode) - activates 1 preset at a time
Cycle - cycles automatically between presets
Multi - activates multiple presets simultaneously
3.CHASE TIME
Displays run time of chases recorded onto preset
4.SPEED
Cycle speed stored onto presets. 1-255 -Slowest to Fastest
5.FADE TIME
Fade time for presets (recommended)
6.SAVE TO USB
Export saved presets and settings for backup
7.LOAD FROM USB
Import saved presets and settings from backup
8.RESET
Master reset
9.VER
Software version
SET UP THE MAIN UNIT CONNECTIONS
prochurchlights.com
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
POWER IN
DMX OUT
RS485
RS232
PANEL
AUDIO
AUDIO
MIC
MIC
IN RECORD
70SO23060008062
Diagram Showing Rear of 512 Channel Version:
1 Connect device to power.
2 Connect DMX output to fixtures or DMX distributor.
3 Connect Wall Panel using RJ45/Cat5e cable.
4 Connect DMX input to lighting console’s output.
INSTALL THE WALL PANEL PRO™
prochurchlights.com
PRO CHURCH LIGHTS
LOVE YOUR LIGHTS™
1 Press tab on rear of Wall Panel to remove the mounting plate.
2 Place mounting plate in desired location and mark screw hole, center cut out area.
3 Make a cut out in your wall where the RJ45 ports will recess.
4 Use the 4 included screws and drywall anchors to mount the plate to the wall.
5 Connect Cat5e cable to rear port (PIN 1). If using multiple Wall Panels, use the second port to
daisy-chain additional Wall Panels together.
6 Insert Wall Panel onto mounting plate by sliding it so that tab (#1) locks the panel into place.
Diagram Showing Rear Wall Panel Pro™: