WALL PANEL PRO™

USER

MANUAL

Copyright ©2024 - All Rights Reserved

Love Your Lights and Wall Panel Pro are Registered

Trademarks of Pro Church Lights

PowerCon is a registered trademark of Neutrik

prochurchlights.com

WALL

PANEL

PRO

THANK YOU

for purchasing the WALL PANEL PRO™ by Pro Church Lights

VIEW THE SETUP VIDEOS

or visit https://support.prochurchlights.com/setup-guides

Scan QR code using mobile device

prochurchlights.com

This device complies with part 15 of the FCC rules.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference,

and (2) This device must accept any interference

received. including interference that may cause

undesired operation.

Manufactured for Pro Church Lights

Distributed by Pro Church Lights USA LLC

Manufactured in China - Serviced in USA

©2024 All Rights Reserved

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

SPECIFICATIONS

DMX Control 512ch and 1024ch Models

Input Current AC100-240v, 50/60hz

Amp Draw 0.50 amps

Wall Panel Material Tempered Glass

Rack Unit Material Metal

IP Rating IP20 / Indoor Use Only

CONTENTS

prochurchlights.com

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

What's In The Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Getting to Know Your Pro Church Lights Device . . . . . . . . . . . . 5

Menu Functions Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Setting Up Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Installing Wall Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Set Up Settings and Presets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

IMPORTANT SAFEGUARDS

READ ALL INSTRUCTIONS BEFORE USING YOUR WALL PANEL PRO™

WARNING - Cancer and Reproductive Harm

For more information visit:

www.P65Warnings.ca.gov

SAVE THESE INSTRUCTIONS

prochurchlights.com

WARNING - Risk of electrical

shock and fire hazard. Use

precaution and awareness when

using this electrical device.

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

WARNING

ALWAYS properly ground to

maintain Class 1 Protection.

DO NOT power the unit if the

cord is frayed or damaged.

DO NOT plug this unit into a

dimmer switch or dimmer pack.

DO NOT expose to liquids, rain or

moisture.

ALWAYS disconnect from power

before making any type of

connection.

This device is for indoor use only.

Using this device in any other

way will void its warranty and

cause unsafe operation.

Regularly inspect the device and

power cord. DO NOT use the

device if there is damage to the

power cord or plug. If the

appliance malfunctions or

has been damaged in any way,

immediately stop use and call

Customer Service. Return the

device to Pro Church Lights for

examination, repair, or

adjustment.

DO NOT remove the cover or service

inside the unit.

ALWAYS use AC power that

complies with local building and

electrical codes and has both

overload and ground fault

protection.

ALWAYS check that your voltage

is compatible with this device

before plugging in the device.

10

WHAT'S IN THE MAIN UNIT BOX

WALL PANEL PRO™ Main Unit

prochurchlights.com

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

3’ 3-Pin DMX Cable

Cat5 Cable

Power Cable

WHAT'S IN THE WALL PANEL BOX

WALL PANEL PRO™ Wall Panel

4 Phillips Head Screw

4 Wall Anchors

GETTING TO KNOW YOUR DEVICE

prochurchlights.com

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

WALL

PANEL

PRO

USB

DISPLAY

MENU

UP

ENTER

DOWN

PRESET

SPEED

WALL

CONSOLE

STOP

RECORD

BLACK

OUT

OFF

ON

Diagram showing front of 512 & 1024 models

10

11

12

13

Number

Description

Function

USB Port

USB for backing up presents and settings

DISPLAY

Displays set up functions

MENU

Used to access the different menu items

UP

Used to adjust settings

DOWN

Used to adjust settings

ENTER

Confirms settings

PRESET 1-8

Buttons for saved presets

+SPEED-

Used if utilizing chase mode

WALL

Activates wall panel mode.

Flashing indicates "active". Static indicates "locked".

10

CONSOLE/STOP

Activates console mode.

When saving presets, this is used as the “stop” button.

11

RECORD

Activates recording of presets.

12

BLACKOUT

Stops DMX output

13

Power switch

Turns unit on and off

GETTING TO KNOW YOUR DEVICE CONT’D

prochurchlights.com

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

POWER IN

DMX OUT

RS485

RS232

PANEL

AUDIO

AUDIO

MIC

MIC

IN RECORD

70SO23060008062

AUDIO

MIC

70SO23060008062

Diagram Showing Rear of 512 Channel Version:

Diagram Showing Rear of 1024 Channel Version: (The 1024 version has a 2nd DMX IN/OUT port)

DMX OUT A

RS485

RS232

PANEL

AUDIO

MIC

IN RECORD A

DMX OUT B

IN RECORD B

Number

Description

Function

POWER INPUT

AC 88 - 256V 50/60Hz

DMX OUT

DMX output to fixtures or distributor

RS232

RS232 control port

PANEL/CENTRAL

Main wall panel connection port

AUDIO

Allows for audio triggers

AUDIO & MIC

Switch between audio port or mic for triggers

MIC

Mic for sound triggers

IN RECORD

DMX input from console

RS485

Allows for additional rack units to be connected

10

DMX OUT B

2nd Universe DMX output

11

IN RECORD B

2nd Universe DMX input

10

11

prochurchlights.com

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

MENU FUNCTIONS REFERENCE

MENU ITEMS AND FUNCTIONS

Map Menu

Function

1. UNIT ID

Set Device ID (used if multiple main units are being used)

2.PLAY MODE

Single (recommended mode) - activates 1 preset at a time

Cycle - cycles automatically between presets

Multi - activates multiple presets simultaneously

3.CHASE TIME

Displays run time of chases recorded onto preset

4.SPEED

Cycle speed stored onto presets. 1-255 -Slowest to Fastest

5.FADE TIME

Fade time for presets (recommended)

6.SAVE TO USB

Export saved presets and settings for backup

7.LOAD FROM USB

Import saved presets and settings from backup

8.RESET

Master reset

9.VER

Software version

SET UP THE MAIN UNIT CONNECTIONS

prochurchlights.com

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

POWER IN

DMX OUT

RS485

RS232

PANEL

AUDIO

AUDIO

MIC

MIC

IN RECORD

70SO23060008062

Diagram Showing Rear of 512 Channel Version:

1 Connect device to power.

2 Connect DMX output to fixtures or DMX distributor.

3 Connect Wall Panel using RJ45/Cat5e cable.

4 Connect DMX input to lighting console’s output.

INSTALL THE WALL PANEL PRO™

prochurchlights.com

PRO CHURCH LIGHTS

LOVE YOUR LIGHTS™

1 Press tab on rear of Wall Panel to remove the mounting plate.

2 Place mounting plate in desired location and mark screw hole, center cut out area.

3 Make a cut out in your wall where the RJ45 ports will recess.

4 Use the 4 included screws and drywall anchors to mount the plate to the wall.

5 Connect Cat5e cable to rear port (PIN 1). If using multiple Wall Panels, use the second port to

daisy-chain additional Wall Panels together.

6 Insert Wall Panel onto mounting plate by sliding it so that tab (#1) locks the panel into place.

Diagram Showing Rear Wall Panel Pro™:

1 2 3 4 5 6 7 8 9 10 11 12 13 14